Advantages And Disadvantages Of Serial Dilution Method카테고리 없음 2020. 2. 18. 20:47
Feb 04, 2009 What are the advantages and disadvantages of the serial dilution - agar plate procedure? The total count includes dead as well as living cells.The advent of a new technology often brings far-reaching benefits well beyond the initial perception of its key advantages. Acoustic dispensing, for example, with the ability to have highly controlled droplet transfers at 2.5-nL increments with exquisite precision and accuracy, does much more than save money by eliminating pipets.It enables new work flows, including those in which multiple pharmaceutical firms have seen dramatic differences in the true success or failure of compounds. This article shows how the use of acoustic dispensing and direct dilution leads to the creation of better compound structures and the potential for faster development of new drugs. Figure 1 – Traditional serial dilutions can be structured with various modifications. This model shows the initial steps of a serial dilution using half-log steps. Other methods may use twofold or tenfold dilutions.
Each transfer step requires contact with the pipet (symbolized by the yellow triangle).While pipet tips can be washed, most groups use new tips to eliminate any chance of carryover. However, multiple contacts also open the technique to problems caused by leachates. 2,3 After a series of diluted samples are generated, a small volume is transferred to the assay plate. This transfer increases the number of disposable tips used or increases the potential for carryover. The serial process increases the error in precision at each successive step. 4 In order to keep the final concentration of dimethylsulfoxide (DMSO) low in the assay, 10% DMSO was used as the diluent.In this example, the final DMSO concentration in the assay is 0.75%.
Note that 10 µ L of sample is used to generate the concentration gradient. The serial dilution technique 1 using pipets is a well-established way to obtain a series of increasingly dilute solutions to understand the effect of dosing. In this technique, a volume of concentrated stock solution is diluted with a liquid. To generate more dilute concentrations, an aliquot of the diluted solution is further diluted with buffer ( Figure 1). Doing a tenfold dilution six times in a row generates a solution that one hopes to have one-millionth the concentration of the initial stock solution. Direct dilution using an acoustic liquid handler.Figure 2 – Direct dilution provides a number of advantages over serial dilution.
When the Labcyte Echo liquid handler is used, the solutions are never in contact with a pipet tip, pin tool, or spray nozzle. This eliminates the potential for both leachates and cross-contamination.Stock solution is transferred directly to the assay wells to generate the same concentrations obtained in serial dilutions. Because the amount of stock solution is so small, the sample can be maintained in pure DMSO to reduce the chance of sample precipitation during dilution. Compounding error is eliminated since samples are not serially diluted.In general, significantly less sample is used to generate the final concentration ranges. Direct dilution also generates less liquid and solid waste, reducing downstream expenses.
Note that after backfill, the concentration of DMSO in the assays is 0.75%. Note also that only 110 nL of sample is used to develop the first four points of the gradient. The last eight points require 255 nL additional sample. The direct dilution method uses far less sample than the serial dilution method.This figure shows only the first four concentrations via direct dilution.
More complete examples covering 12 half-log steps are covered in the literature. 6,9 Direct dilution follows a simpler process. 5–9 Controlled volumes of the same concentrated stock solution are transferred directly to assay wells to achieve the desired end concentration. Essential to direct dilution is the ability to accurately transfer extremely small volumes of stock solution, which is generally not possible with pipets.The Labcyte ® Echo ® acoustic liquid handler ( Labcyte Inc., Sunnyvale, CA) is frequently used in the pharmaceutical industry to generate concentration ranges via direct dilution ( see Figure 2). In a recent paper, 10 Ekins et al. Analyzed data generated by researchers 11,12 at the pharmaceutical giant, AstraZeneca ( AZ, Wilmington, DE).Those researchers ran experiments that generated results that deviated unexpectedly from what one would anticipate.
They ran dose–response experiments to generate IC 50 values in order to determine the potency of a series of newly synthesized compounds (substituted diaminopyrimidines) as an anti-cancer therapeutic against a receptor (EphB4) that appears to have multiple roles in cancer promotion and suppression. The IC 50 value of a chemical is that concentration that reduces the effect of the enzyme by 50%. The lower the IC 50 value, the more potent the compound, i.e., it requires lower concentrations to achieve 50% inhibition.
The goal is to find compounds that work at the lowest doses, because those compounds are more likely to lead to safe and efficacious drugs. Direct dilution vs serial dilution method The AZ researchers generated their range of compound concentrations using two different techniques. In the first instance, they performed serial dilutions with 5% DMSO as the diluent.They also generated a concentration gradient with a direct dilution using the Labcyte Echo system. Table 1 – IC50 values for 14 diaminopyrimidines. The data generated by the AZ researchers are summarized in Table 1. For each of the 14 compounds tested, the IC 50 value generated by the direct dilution/acoustic method showed greater effect at lower doses than the value generated by the serial dilution/pipet method.
The difference was far from trivial, with compounds 5 and 7 being more than 250 times more “active” with the acoustic method. The data also show that there was no systemic error that pushed all values in a consistent manner.There was no correlation between the IC 50 values or the rank order of the two data sets. It is important to note that without direct dilution achieved through acoustic liquid handling, the AZ researchers would have obtained indicators that the diaminopyrimidines were poor inhibitors of EphB4. It seems unlikely that they would have chosen to further investigate the potential of these compounds if they had relied on the serial dilution/pipet method.
We compared IC 50 values derived via each dilution process to a number of properties of the compounds in an effort to determine what might cause the differences between them. We found no correlation between the IC 50 values when compared to hydrophobicity (logP), polar surface area (PSA), isoelectric point (pI), molecular weight (MW), molar refractivity (A), hydrogen bond donors (HBD), hydrogen bond acceptors (HBA), or charge. While these results are quite disturbing, it is not possible at this point to determine which process yields the correct IC 50 data.All that can be said is that there is a substantial apparent difference between the techniques based on the measured values. We generated pharmacophores based on the structures of the compounds and their IC 50 values.
A pharmacophore is a computer model that suggests the types, kinds, and spatial proximities of binding features in the target (EphB4 receptor). One pharmacophore was generated from the data from each dispensing and dilution technique.
Table 2 – Comparison of pharmacophores. As expected from such different IC 50 data, the two pharmacophores are very different ( Table 2). The fit of the tested molecules to the developed pharmacophore was much better with the acoustic data (r = 0.92) than with the pipet-based technique (r = 0.80).Most notably, the pharmacophore generated by direct dilution with acoustics shows the presence of two hydrophobic binding regions, while the serial dilution by pipet tips method suggests a complete absence of these regions. Normally, a medicinal chemist with the help of a computational modeler would use the generated pharmacophores to generate new compounds that might bind more tightly and more specifically to the active site of the target molecule. In this case, the chemist would be faced with a significant problem which path should be followed? Should the next generation of compounds include hydrophobic regions or not?
How many hydrogen bond donors and acceptors should be designed into the structure and where should they be located relative to each other? Until further experiments are done, it is not possible to determine which pharmacophore more closely models the actual target.Fortunately, we were able to find additional publications that tested the same EphB4 receptor with similar diaminopyrimidines. 13 This gave us the opportunity to test the predictive capabilities of the two pharmacophore models we had generated. We found that the pharmacophore generated via serial dilutions using a pipet system was completely nonpredictive. The predicted order of potency was compared to the measured value of potency and a negligible correlation value of 0.184 was obtained. On the other hand, the acoustic pharmacophore suggested that the compounds tested in the new set would be very potent inhibitors.
The IC 50 values generated by the AZ researchers placed these compounds as extremely active.Importantly, the acoustic pharmacophore correctly predicted the ranking of their potency. These results strongly suggest that the data generated by the acoustic technique were superior to those generated by the automated pipet. Significantly, additional data show that the acoustic pharmacophore closely resembled the actual binding site of the native target.Generation of pharmacophores from X-ray data X-ray crystallography data are often considered to be the gold standard when describing the actual physical shape of a protein. Published X-ray data of the EphB4 receptor 14–17 allowed us to generate pharmacophores directly from the physical structure. A series of eight pharmacophores were generated from the X-ray data. All eight were very similar in structure and showed binding features positioned in space with close similarity.All of them showed the presence of hydrophobic binding regions.
As mentioned previously, the acoustic data also suggested the importance of these regions while the pipet-based technique discounted them. The average results of the eight pharmacophores are included in Table 2.It is clear that, in this case, the direct dilution technique using acoustic liquid handling generated better data and a pharmacophore that correctly predicted the activity of new compounds.
Additionally, the pharmacophore generated by the technique was very similar to the pharmacophores from the X-ray data. The serial dilution with pipets technique failed markedly on both fronts. Was this particular case using the EphB4 receptor an anomaly? Was there something special about these compounds that caused the deviation from the expected?It appears that the answer is no. Other work presented by AstraZeneca and Bristol-Myers Squibb ( BMS, New York, NY) suggests that this type of result is common. AZ presented a poster 18 that measured the inhibition of 11,000 compounds.
Cell Counting Using Serial Dilution
There was a marked difference between the two techniques with the acoustic technique suggesting significantly more active compounds. They reported that the acoustic method generated a much lower rate of false positives and false negatives than pipet-based techniques. BMS showed results 19 on over 1000 compounds that also suggested that compounds tended to be more active when transferred via the acoustic method.
Why would that be the case?We believe that the intimate contact between the dilute solutions generated by serial dilutions, the containers in which they are mixed, the pipet tips with which they are moved, and the inaccuracy of dispensing all contribute to the deleterious effect of pipetting. As volumes are miniaturized from 96-well format to 1536-well format, the surface-to-volume ratio increases by a factor of 4 and allows more potential for material to be adsorbed from solution. This makes the actual concentration of compound in solution much less than anticipated.In addition, the adsorption is not limited to hydrophobic binding. The results of these experiments as well as those performed by various pharmaceutical companies show a negligible correlation to logP. While a dependence on logP has been shown in certain specific cases, we believe that there are other driving forces.In any case, the elimination of serial dilution should benefit the discovery process.
Conclusion We began this work because we realized that the databases used by many researchers, both public and private, would have limited utility if the data contained in them were dependent on liquid handling techniques.Since there are no metadata included in the databases to differentiate between compounds transferred acoustically versus those transferred via pipets, the results would be an amalgamation of all and would yield meaningless results. This would lead researchers down unfruitful paths as they design the next set of compounds. We urge researchers, at a minimum, to include the method used to make their dilutions as well as the method used to transfer solutions in their data. Further, we strongly encourage researchers, especially in the pharmaceutical industry, to determine specifically what factors of the compounds lead to such differences in results and, in the meantime, use direct dilution with acoustic dispensing to avoid the now-exposed problems inherent to the more traditional method.
Advantages And Disadvantages Of OilWithout this understanding, researchers are likely to spend time and resources developing new compounds based on assay artifacts rather than on real biological mechanisms. This understanding should allow us to create better drugs more quickly, generate biological tools with greater specificity, and reduce wasted effort significantly. As a postscript, we are aware that not all scientists perform high-throughput screening. We believe this paper to be relevant to small-scale experiments using serial dilution and manual pipetting. They, too, may be at risk of erroneous data generation. References.McDonald, G.R.; Hudson, A.L.
Bioactive contaminants leach from disposable laboratory plasticware. Science 2008, 322, 917; doi: 10.1126/science.1162395. Belaiche C.; Holt, A. Nonylphenol ethoxylate plastic additives inhibit mitochondrial respiratory chain complex I. 2009, 55, 1883–4; doi: 10.1373/clinchem.2009.130054.Cesarek, J.; Nie, D. New Tool for Automating Serial Dilutions for Activity Confirmation Experiments. Poster, Lab Automation Exhibition and Conference, San Jose, CA, 2005.
Olechno, J.; O’Connell, J. Improving IC 50 Analyses by Reducing Compound Waste, Compound Precipitation, Accumulated Error and Consumables Cost.Poster, LabAutomation, Palm Springs, CA, 2006.
Olechno, J.; Shieh, J. Improving IC 50 results with acoustic droplet ejection. 2006, 11, 240–6.Serial vs direct dilution: time to apply new thinking to IC 50 determination and dose-response analysis? World 2007 Spring, 36–50. Turmel, M.; Itkin, Z. An innovative way to create assay ready plates for concentration response testing using acoustic technology.2010, 15, 297–305; doi: 1016/j.jala.2009.04.002.
Harris, D.; Olechno, J. Gradient, contact-free volume transfers minimize compound loss in dose-response experiments. 2010, 15, 86–94; doi: 1027.Ekins, S.; Olechno, J. Dispensing processes impact apparent biological activity as determined by computational and statistical analyses.PLoS ONE 8(5): e62325;; doi: 10.1371/journal.pone.0062325; 2013.
Barlaam, B.C.; Ducray, R.2,4-Diamino-pyrimidine derivatives. WO 2009/010794 A1, 2009. Barlaam, B.C.; Ducray, R.
Pyrimidine derivatives for inhibiting Eph receptors. 7,718,653 B2, 2010. Barlaam, B.C.; Ducray, R.N'-(phenyl)-N-(morpholin-4-yl-pyridin-2-yl)-pyrimidine-2,4-diaminederivatives as EPHB4 kinase inhibitors for the treatment of proliferative conditions. WO 2008/132505 A1, 2008.Bardelle, C.; Cross, D.
Inhibitors of the tyrosine kinase EphB4.Part 1: structure-based design and optimization of a series of 2,4-bis-anilinopyrimidines. 2008, 18, 2776–80; doi: 10.1016/j.bmcl.2008.04.015. Bardelle, C.; Coleman, T. Inhibitors of the tyrosine kinase EphB4.
Part 2: structure-based discovery and optimisation of 3,5-bis substituted anilinopyrimidines. 2008, 18, 5717–21; doi: 10.1016/j.bmcl.2008.09.087.
Bardelle, C.; Barlaam, B.Inhibitors of the tyrosine kinase EphB4. Part 3: identification of non-benzodioxole-based kinase inhibitors. 2010, 20, 6242–5; doi: 10.1016/j.bmcl.2010.08.100. Barlaam, B.; Ducray, R.Inhibitors of the tyrosine kinase EphB4. Part 4: discovery and optimization of a benzylic alcohol series. 2011, 21, 2207–11; doi: 10.1016/j.bmcl.2011.03.009.
Wingfield, J. Impact of acoustic dispensing on data quality in HTS and hit confirmation. 2012, Manchester, U.K.Spicer, T.; Fitzgerald, Y. Pharmacological evaluation of different compound dilution and transfer paradigms on an enzyme assay in low volume 384-well format. 2005, Boston, MA.Joe Olechno and Mark Fischer-Colbrie are with Labcyte Inc., 1190 Borregas Ave., Sunnyvale, CA 94089, U.S.A.; tel.: 408-747-2000, ext. 161; e-mail:. Sean Ekins is with Collaborations in Chemistry, Fuquay-Varina, NC, U.S.A.
Williams is with the Royal Society of Chemistry, Wake Forest, NC, U.S.A.Huge Micro Problem As you know, bacteria are everywhere, invisible to the naked eye, yet influencing every environment on Earth. What happens when you need to know how many individual bacterial cells are contaminating a food, living in an environmental sample, or growing in a culture tube?You need some method for counting the bacteria accurately.
But, it is not uncommon for a liquid culture of bacteria to have a billion cells in every milliliter of media. Think about that for one second. In your kitchen, you probably have a teaspoon. Every teaspoon has about 5 milliliters.
That means that every teaspoon of liquid could potentially have 5 billion bacteria in it. Even if you counted one bacteria every second, it would take you over 150 years to get to 5 billion!Obviously, this is not a viable option. So, what can you do? You need fewer bacteria to count. Ideally, you want to only have to count between 30 and 300 bacteria, a range of numbers that takes only at most a few minutes to count. But, how do we get there?Serial Dilution The answer is through dilution. If you simply pull out a smaller, exact quantity of culture liquid, you could count those bacteria and, based on how much you pulled out of the total, you can determine how many bacteria are in your original sample.Sounds easy, right?
But first, one more analogy: you have billions of bacterial cells and need to get down to 30 to 300. In order to do that, you would have to dilute your sample about 10 million-fold. To do this, you would need to take about 15 milliliters of your sample, about 3 teaspoons, and dilute it into your swimming pool!
I doubt this is a viable option, especially if you're working in a cramped lab space. So instead, let's not dilute just once. We can dilute once, then dilute this dilution, only to dilute this dilution, and so on until we get to the appropriate concentration of cells.This is called a serial dilution. A serial dilution is a series of dilutions used to reduce a dense culture of cells to a more usable concentration. Each dilution will reduce the concentration of bacteria by a specific amount. So, by calculating the total dilution over the entire series, it is possible to know how many bacteria you started with. The best way to fully grasp serial dilutions is to try out the procedure yourself.
How to Perform a Serial Dilution I'm going to walk you through an example serial dilution using the easiest method, but, once you grasp the concept, you can change the actual numbers to whatever works best for you and do it the same way.To start, we need 10 milliliters (10 ml) of your original bacterial culture (labeled OBC). Before we start diluting, we need to prepare several dilution blanks, which are tubes containing your diluting liquid in exact quantities.
Your liquid could be growth media, saline, sterile water, or any other appropriate liquid. For this example, we need 5 dilution blanks, numbered 1-5.
In each tube, we need exactly 9 ml of liquid media. The reason we need 9 ml will become apparent soon.The tubes should be lined up like this: How to line up tubes for serial dilution example The first step is to gently shake or swirl the tube. This will ensure that your cells are evenly distributed in the tube.If your cells settle to the bottom, and you remove liquid without swirling, you run the risk of not getting enough cells, invalidating your final count. Remember to always swirl the tube before removing liquid. Once swirled, carefully transfer exactly 1 ml from your OBC Tube to Tube 1.Now, you should have 10 ml of liquid in Tube 1. Exactly one-tenth of your cells are now in a new tube with a final volume of 10 ml.
You just performed a 1 in 10 dilution, or it could be written 1/10. 1 is the volume you transferred, and 10 is the final volume of the tube after the transfer.Now, you are done with tube OBC, and Tube 1 becomes the next tube to be diluted. Like we did before, swirl your tube before transferring 1 ml from Tube 1 into Tube 2. Again, exactly one-tenth of your cells in Tube 1 are transferred to Tube 2, with a final volume of 10 ml.Tube 1 should have exactly 9 ml left. Tube 2 now contains a 1 in 10 dilution of Tube 1.
In order to calculate the total dilution from Tube OBC, simply multiply your two dilutions: 1/10 X 1/10 = 1/100.So far, you have performed a 1/100 dilution from the original bacterial culture. You want to follow the same procedure for the remaining dilution blanks: 1 ml from Tube 2 is transferred to Tube 3; 1 ml from Tube 3 is transferred to Tube 4; and, finally, 1 ml from Tube 4 is transferred to Tube 5. Each transfer is another 1 in 10 dilution. To calculate the final dilution, simply multiply all the dilutions together: 1/10 X 1/10 X 1/10 X 1/10 X 1/10 = 1/100,000. Now we might have a reasonable number of cells to count. To finish the technique, let's imagine we count the cells in Tube 5 and find 50 total cells, right in the desired 30 to 300 zone. In order to determine how many cells we started with in our original culture, all you need to do is multiply the cell count by the total dilution: 50 X 100,000 = 5,000,000 bacterial cells in our original 10 ml sample.I bet you would rather count to 50 than 5 million!
It is important to note that you can use any volumes here. If your dilution blanks are 6 ml, and you are transferring 1 ml, the dilution would be 1/7. The math is exactly the same: 1/7 X 1/7 X 1/7 X 1/7 = 1/2401. You also don't need to have the same final volume in every tube.
You can dilute 1/2, then 1/5, then 1/8.Simply multiply as before to get the final dilution: 1/2 X 1/5 X 1/8 = 1/80. Now you might be wondering how we count the tiny cells. There are several methods that could be used, but we will use the culture plate method.
We can take a sample of Tube 5 and grow the cells on a culture plate. Then, once the bacteria start to grow, they form colonies that eventually get large enough to see. Then, we can count the colonies and back calculate to find the original concentration of bacteria in our sample.You have solved what started out to be a pretty daunting problem! Lesson Summary Let's briefly review serial dilutions. A serial dilution is a series of sequential dilutions used to reduce a dense culture of cells to a more usable concentration. The easiest method is to make a series of 1 in 10 dilutions. In this method, exactly 1 ml of each successive dilution is transferred into exactly 9 ml of liquid in a dilution blank, creating a 1/10 dilution.
In order to calculate the final dilution, all you need to do is multiply the 1/10 X 1/10, continuing like this for each step in the dilution.To determine exactly how many cells you started with, simply take the number of colonies you counted, and multiply it by your final dilution factor. Learning Outcomes Once you've completed this lesson, you may be able to. Create a serial dilution and recognize its purpose.Identify the steps necessary for developing a serial dilution. Know how to count bacteria cells.goodtextfluid.